What we hang, tape, finish & paint.
Drywall scopes priced by assembly grade, not by sheet count. Every line item below is a measured deliverable — not a vibe.
- S-01
Type X fire-rated assemblies
5/8 in. · 1-hr / 2-hr UL listed
Garage-to-living, demising walls, mechanical room enclosures. Detailing meets IBC 718 and the AHJ inspector's exact reading of the code.
- Fire rating max
- 2 hr.
- S-02
STC-rated acoustic walls
STC 33 / 50 / 60 class
Resilient channels, double-stud lines, green-glue lamination, mineral-wool fills. Bedrooms next to mechanical rooms become quiet.
- Acoustic max
- STC 60
- S-03
High-performance thermal envelopes
R-21 / R-30 / R-40 wall systems
Air-sealed gypsum air barriers, taped seams to ASTM E2178 tolerances, blower-door-ready details. The board is part of the envelope.
- Envelope max
- R-40
- S-04
Level 4 / Level 5 finish
GA-214 compliant
Skim-coated, sanded, raked-light verified. Specified for raking light, glossy paint, and clients who notice the seam shadow.
- Finish grade
- L5
- S-05
Ceiling systems
Suspended · fire-rated · acoustic
Direct-applied or suspended grid, fire-rated lid assemblies, acoustic dampening for open-plan main floors that turn into echo chambers.
- Span tested
- 24 ft.
- S-06
Repair, patch, texture match
Knockdown · orange peel · smooth
Post-leak, post-electrical, post-remodel. We match Anchorage's 1990s spray patterns and modern Level-4 smooths without a visible seam.
- Match window
- ± 1%
- S-07
Wet-area cement-board detail
ANSI A108.11 · waterproofed
Bathroom and steam-room substrates with proper return-edge flashing and seam taping ready for tile or solid-surface install.
- Substrate
- 1/2 in.
- S-08
Interior painting
Low-VOC · arctic-rated
Sealer-primer-finish in cold-tolerant systems. Cabinet boxes, trim millwork, full interior repaints. Drywall and paint as one scope.
- Coats spec'd
- 3
The board, the seam, the field.
Six anchored captures from recent envelope work. Captions are measured deliverables — neighborhood, scope, and the spec that mattered.
South Anchorage remodel
Hillside · AnchorageLevel-5 finish · 2,400 sf · whole-floor repaint
Demising-wall measure-up
Midtown · AnchorageSTC 50 assembly · resilient channel layout · pre-board QC
Garage-to-living fire wall
Sand Lake · Anchorage5/8 in. Type X · 1-hr UL 305 · taped + skim
Hung-board day, full crew
South Addition · Anchorage5/8 in. on 16 oc · 220 sheets · 1 day production
Pre-board envelope QC
Spenard · AnchorageStud-line laser check · ±1/16 in. tolerance · envelope sign-off
Plaster-repair texture match
Eagle RiverKnockdown reset · 1995 spray pattern · 12 sf area
Whole-home repaint
Chugiak3-coat low-VOC system · 4,100 sf interior · 6 day production
Open-plan ceiling acoustic
Spenard · AnchorageSuspended sound-rated grid · STC 45 lid · main-level open plan
Crew on-site, full PPE
Midtown · AnchorageDust-control sequence · negative-pressure room · 2-person tape crew
Cabinet-box repaint
Sand Lake · AnchorageHVLP spray finish · 38 doors · 14 drawer fronts
We don’t have public reviews yet. Here’s what the crew wrote down instead.
CJ Contractors & Painting is rebuilding its public review presence in 2026. Until then, these are the foreman’s field notes — not invented customer quotes.
- F-NOTE / 012025-02-14
Sand Lake garage demising wall
Two-hour assembly. Crew flagged the existing top-plate gap before board went up — sealed and re-inspected. Sometimes the most important drywall decision happens before the first sheet hangs.
— Foreman log - F-NOTE / 022024-11-03
Hillside primary suite
Raking light off the south windows turned an ordinary Level-4 finish into a problem. Came back with skim, re-sanded under work lights, and re-inspected at 8 am sun. The seam disappears at every hour now.
— QC pass - F-NOTE / 032024-08-22
Eagle River basement build-out
Mechanical room shares a wall with the new bunk room. Spec called STC 35; we proposed STC 50 with resilient channel and mineral wool. Owner can’t hear the boiler kick anymore.
— Scope upgrade
Licensed, insured, and built to the actual code.
- LicenseAK Business LicenseActive · Anchorage municipality
- InsuranceGeneral liabilityCarried on every job
- StandardsGA-214 Level 5Gypsum Association finish standard
- FireIBC 718 detailingType X 1-hr / 2-hr assemblies
- AcousticSTC 50+ capableASTM E90 measured assemblies
- ThermalR-21 to R-40Envelope-grade detailing
Built around climate zone 7.
Heating-degree days drive every assembly we hang. The colder the bearing, the harder the envelope works.
- Anchorage (Bowl)61.218 N · 149.900 WHDD 10,816
- South Anchorage61.130 N · 149.910 WHDD 10,820
- Hillside61.150 N · 149.770 WHDD 10,910
- Eagle River61.321 N · 149.567 WHDD 11,160
- Chugiak61.392 N · 149.479 WHDD 11,210
- Girdwood (winter)60.957 N · 149.166 WHDD 11,940
- Wasilla (commercial)61.581 N · 149.443 WHDD 12,020
Tell us about the wall assembly.
We’ll respond within one business day with assembly options, sheet counts, and an honest schedule.