CJ
Drywall · Painting · Anchorage AK
(907) 244-0404Call (907) 244-0404
CJ
CJ ContractorsDrywall & Painting · Anchorage AK
801 E 82nd Ave · Anchorage AK · LIC + INS

Drywall built for Anchorage envelopes. R-21 to R-40 ready.

Type X fire-rated assemblies, STC 50+ acoustic walls, and high-performance thermal enclosures hung, taped, and finished to spec. Drywall is part of the envelope — we treat it like it.

Request a wall-assembly quote(907) 244-0404
Fire rating
Type X
5/8 in.
Acoustic class
STC 60
max assembly
Envelope R-value
R-40
passive ready
Climate zone
Zone 7
10,816 HDD
Envelope Performance Sweep · scroll to compare

Same room. Four wall assemblies. Sixteen-hundred-dollar swing in winter heat.

cavity insulationresilient channel
wall section · interior right
  1. 01 / 0430 min. fire
    Code minimum
    2x4 stud · R-13 batt · 1/2 in. board
  2. 02 / 041 hr. fire
    Standard envelope
    2x6 stud · R-21 batt · 5/8 in. Type X
  3. 03 / 041 hr. fire
    Quiet-room build
    2x6 stud · R-30 mineral wool · 5/8 in. Type X · resilient channel
  4. 04 / 042 hr. fire
    Passive-ready
    2x8 staggered · R-40 mineral wool · double 5/8 in. Type X + green-glue lamination
Live readout · Anchorage HDD 10,816
Whole-wall R-value
R-13.0
Modeled heat cost / yr
$2,400 / yr
Sound transmission class
STC 33
Scope · 08 trades inside one envelope

What we hang, tape, finish & paint.

Drywall scopes priced by assembly grade, not by sheet count. Every line item below is a measured deliverable — not a vibe.

  1. S-01

    Type X fire-rated assemblies

    5/8 in. · 1-hr / 2-hr UL listed

    Garage-to-living, demising walls, mechanical room enclosures. Detailing meets IBC 718 and the AHJ inspector's exact reading of the code.


    Fire rating max
    2 hr.
  2. S-02

    STC-rated acoustic walls

    STC 33 / 50 / 60 class

    Resilient channels, double-stud lines, green-glue lamination, mineral-wool fills. Bedrooms next to mechanical rooms become quiet.


    Acoustic max
    STC 60
  3. S-03

    High-performance thermal envelopes

    R-21 / R-30 / R-40 wall systems

    Air-sealed gypsum air barriers, taped seams to ASTM E2178 tolerances, blower-door-ready details. The board is part of the envelope.


    Envelope max
    R-40
  4. S-04

    Level 4 / Level 5 finish

    GA-214 compliant

    Skim-coated, sanded, raked-light verified. Specified for raking light, glossy paint, and clients who notice the seam shadow.


    Finish grade
    L5
  5. S-05

    Ceiling systems

    Suspended · fire-rated · acoustic

    Direct-applied or suspended grid, fire-rated lid assemblies, acoustic dampening for open-plan main floors that turn into echo chambers.


    Span tested
    24 ft.
  6. S-06

    Repair, patch, texture match

    Knockdown · orange peel · smooth

    Post-leak, post-electrical, post-remodel. We match Anchorage's 1990s spray patterns and modern Level-4 smooths without a visible seam.


    Match window
    ± 1%
  7. S-07

    Wet-area cement-board detail

    ANSI A108.11 · waterproofed

    Bathroom and steam-room substrates with proper return-edge flashing and seam taping ready for tile or solid-surface install.


    Substrate
    1/2 in.
  8. S-08

    Interior painting

    Low-VOC · arctic-rated

    Sealer-primer-finish in cold-tolerant systems. Cabinet boxes, trim millwork, full interior repaints. Drywall and paint as one scope.


    Coats spec'd
    3
Job log · select projects 2023–2025

The board, the seam, the field.

Six anchored captures from recent envelope work. Captions are measured deliverables — neighborhood, scope, and the spec that mattered.

  • Interior of a south Anchorage home under renovation with drywall finishing in progress.
    P-01
    L5

    South Anchorage remodel

    Hillside · Anchorage

    Level-5 finish · 2,400 sf · whole-floor repaint

  • Drywall installer measuring a sheet of board for a demising wall in a midtown Anchorage build.
    P-02
    STC 50

    Demising-wall measure-up

    Midtown · Anchorage

    STC 50 assembly · resilient channel layout · pre-board QC

  • Drywall crew fastening Type X board for a garage-to-living fire wall.
    P-03
    1 hr.

    Garage-to-living fire wall

    Sand Lake · Anchorage

    5/8 in. Type X · 1-hr UL 305 · taped + skim

  • Crew member fastening drywall to wood framing on a high-production hanging day.
    P-04
    220 sht.

    Hung-board day, full crew

    South Addition · Anchorage

    5/8 in. on 16 oc · 220 sheets · 1 day production

  • Builder using a level to confirm stud-line plane before drywall hang.
    P-05
    ±1/16

    Pre-board envelope QC

    Spenard · Anchorage

    Stud-line laser check · ±1/16 in. tolerance · envelope sign-off

  • Close-up of a gloved hand applying plaster to a wall during a repair texture match.
    P-06
    12 sf

    Plaster-repair texture match

    Eagle River

    Knockdown reset · 1995 spray pattern · 12 sf area

  • Finished interior of an Anchorage-area home after a full-house repaint.
    P-07
    4,100 sf

    Whole-home repaint

    Chugiak

    3-coat low-VOC system · 4,100 sf interior · 6 day production

  • Open-plan room interior after acoustic ceiling system installation.
    P-08
    STC 45

    Open-plan ceiling acoustic

    Spenard · Anchorage

    Suspended sound-rated grid · STC 45 lid · main-level open plan

  • Drywall crew on site wearing full personal protective equipment during a tape and finish day.
    P-09
    PPE A

    Crew on-site, full PPE

    Midtown · Anchorage

    Dust-control sequence · negative-pressure room · 2-person tape crew

  • Cabinet boxes mid-repaint in a residential kitchen.
    P-10
    38 doors

    Cabinet-box repaint

    Sand Lake · Anchorage

    HVLP spray finish · 38 doors · 14 drawer fronts

Field notes · from the foreman’s log

We don’t have public reviews yet. Here’s what the crew wrote down instead.

CJ Contractors & Painting is rebuilding its public review presence in 2026. Until then, these are the foreman’s field notes — not invented customer quotes.

  1. F-NOTE / 012025-02-14

    Sand Lake garage demising wall

    Two-hour assembly. Crew flagged the existing top-plate gap before board went up — sealed and re-inspected. Sometimes the most important drywall decision happens before the first sheet hangs.

    Foreman log
  2. F-NOTE / 022024-11-03

    Hillside primary suite

    Raking light off the south windows turned an ordinary Level-4 finish into a problem. Came back with skim, re-sanded under work lights, and re-inspected at 8 am sun. The seam disappears at every hour now.

    QC pass
  3. F-NOTE / 032024-08-22

    Eagle River basement build-out

    Mechanical room shares a wall with the new bunk room. Spec called STC 35; we proposed STC 50 with resilient channel and mineral wool. Owner can’t hear the boiler kick anymore.

    Scope upgrade
Credentials · what we carry, what we follow

Licensed, insured, and built to the actual code.

  1. License
    AK Business License
    Active · Anchorage municipality
  2. Insurance
    General liability
    Carried on every job
  3. Standards
    GA-214 Level 5
    Gypsum Association finish standard
  4. Fire
    IBC 718 detailing
    Type X 1-hr / 2-hr assemblies
  5. Acoustic
    STC 50+ capable
    ASTM E90 measured assemblies
  6. Thermal
    R-21 to R-40
    Envelope-grade detailing
Coverage · Anchorage municipality + Matsu south

Built around climate zone 7.

Heating-degree days drive every assembly we hang. The colder the bearing, the harder the envelope works.

  1. Anchorage (Bowl)
    61.218 N · 149.900 W
    HDD 10,816
  2. South Anchorage
    61.130 N · 149.910 W
    HDD 10,820
  3. Hillside
    61.150 N · 149.770 W
    HDD 10,910
  4. Eagle River
    61.321 N · 149.567 W
    HDD 11,160
  5. Chugiak
    61.392 N · 149.479 W
    HDD 11,210
  6. Girdwood (winter)
    60.957 N · 149.166 W
    HDD 11,940
  7. Wasilla (commercial)
    61.581 N · 149.443 W
    HDD 12,020
Request · envelope-grade quote

Tell us about the wall assembly.

We’ll respond within one business day with assembly options, sheet counts, and an honest schedule.

Or call (907) 244-0404